ULTRASTRUCTURAL ANALYSIS OF THE SURFACE CHANGES ON THE NICKEL-TITANIUM ENDODONTIC INSTRUMENTS AFTER MULTIPLE USE

  • Nenad Stošić Odeljenje za Bolesti zuba i endodonciju, Klinika za Stomatologiju, Medicinski fakultet, Univerzitet u Nišu, Niš, Srbija.
  • Jelena Popović Department of Restorative Dentistry and Endodontics, Clinic of Dentistry, Faculty of Medicine, University of Niš, Niš, Serbia.
  • Marija Anđelković Apostolović Medical Statistics and Informatics, Public Health Institute, Faculty of Medicine, University of Niš, Niš, Serbia
  • Aleksandar Mitić Department of Restorative Dentistry and Endodontics, Clinic of Dentistry, Faculty of Medicine, University of Niš, Niš, Serbia.
  • Marija Nikolić Department of Restorative Dentistry and Endodontics, Clinic of Dentistry, Faculty of Medicine, University of Niš, Niš, Serbia.
  • Radomir Barac Department of Restorative Dentistry and Endodontics, Clinic of Dentistry, Faculty of Medicine, University of Niš, Niš, Serbia.
Keywords: Endodontic instruments, nickel-titanium, damages, SEM.

Abstract


One of the primary goals in endodontics is efficient cleaning and shaping of the root canal while maintaining its original configuration. Numerous studies highlight the advantage of using nickel-titanium instruments and the most important is their high flexibility and the ability to penetrate the curved canals. The aim of this study was to analyze the ultrastructure of the surface of nickel-titanium endodontic files before and after use. Eighty-four instruments were included in this study. The instruments were used one, three and six times for root canal preparation on extracted upper premolars. The analysis was performed based on the number of uses and the size of the instruments. Changes on flat surfaces in the grooves of the instruments, defects of the cutting edges and fractures were evaluated. The surface ultrastructure was analyzed on a scanning electron microscope (SEM). SEM analysis showed irregularities on the surfaces of the new instruments. Surface defects and damage of the cutting edges were present after the first use. After three uses, the damage was more evident in instruments of all sizes. After six uses, all instruments showed damage of the cutting edges, and a significant number of fractures were observed. Irregularities on the working parts are already noticed on the new endodontic instruments and originate from the production process. The first signs of damage appear after the first use. In order to prevent errors in clinical work during root canal preparation, it is recommended that the number of instruments uses should be limited.

References

1. Chianello G, Specian VL, Hardt LCF, Raldi DP, Lage-Marques JL, Ha bitante SM. Surface finishing of unused rotary endodontic instruments: A SEM study. Braz Dent J 2008; 19: 109-113. http://dx.doi.org/10.1590/s0103-64402008000200004
2. Peters OA. Current challenges and concepts in the preparation of root canal systems. J Endodont 2004; 30: 559-567. http://dx.doi.org/10.1097/01.don.0000129039.59003.9d.
3. Orhan ЕО, Ertugrul IF. Cyclic fatigue life of novel rotary compactors: A scanning electron microscopy evaluation. Microsc Res Tech 2020; 83: 66-71. http://dx.doi.org/10.1002/jemt.23389
4. Zuolo MI, Walton RE. Instrument deterioration with usage: nickel titaniun versus stainless steel. Quintessence Int 1997; 28: 397-402. PMID: 9477904
5. Guelzow A, Stamm O, Martus P, Kielbassa AM. Comparative study of six rotary nickel-titanium systems and hand instrumentation for root canal preparation. Int Endod J 2005; 38: 743-752. http://dx.doi.org/10.1111/j.1365-2591.2005.01010.x.
6. Hulsmann M, Donnermeyer D, Schafer E. A critical appraisal of studies on cyclic fatigue resistance of engine-driven endodontic instruments. Int Endod J 2019, 52: 1427-1445. http://dx.doi.org/ 10.1111/iej.13182
7. Pallavi Reddy Y, Kavita S, SubbaRao CV. Cyclic fatigue testing of three different rotary nickel titanium endodontic instruments in simulated curved canals - an in vitro SEM analysis. Journal of Clinical and Diagnostic Research. 2014; 8: 211-213. http://dx.doi.org/10.7860/JCDR/2014/7569.4062
8. Elmsallati EA, Wadachi R, Ebrahim AK, Suda H. Debris retention and wear in three different nickel-titanium rotary instruments. Aust Endod J 2006; 32: 107-111. http://dx.doi.org/10.1111/j.1747-4477.2006.00029.x.
9. Yamazaki-Arasaki AK, Cabrales RJS, Kleine BM, Araki AT, Dos Santos M, Prokopowitsch I. Qualitative analysis of files of four different rotary systems, before and after being used for the twelth time. Microcs Res Techniq 2013; 76: 79-85. http://dx.doi.org/10.1002/jemt.21021
10. Alapati SA, Brantley WA, Svec TA, Powers JM, Mitchell JC. Scanning electron microscope observations of new and used nickel-titanium rotary files. J Endodont 2003; 29: 667-669. http://dx.doi.org/10.1097/00004770-200310000-00014.
11. Plotino G, Grande NM, Cordaro M, Testarelli L, Gambarini G. A review of cyclic fatigue testing of nickel-titanium rotary instruments. J Endodont 2009; 35: 1469-1476. http://dx.doi.org/10.1016/j.joen.2009.06.015
12. Vieira EP, Nakagawa RKL, Buono VTL, Bahia MGA. Torsional behavior of rotary NiTi ProTaper instruments after multiple clinical use. Int Endod J 2009; 42: 947-953. http://dx.doi.org/10.1111/j.1365-2591.2009.01602.x.
13. Fišerová E, Chvosteková M, Bjlašková S, Bumbálek M, Zdenjk J. Survival Analysis of Factors Influencing Cyclic Fatigue of Nickel-Titanium Endodontic Instruments. Advances in Materials Science and Engineering Volume 2015, Article ID 189703, 6 pages. http://dx.doi.org/10.1155/2015/189703.
14. Luzi A, Forner L, Almenar A, Llena C. Microstructure alterations of rotary files after multiple simulated operative procedures. Med Oral Patol Oral Cir Bucal 2010; 15: 658-662. http://dx.doi.org/10.4317/medoral.15.e658.
15. Thompson SA. An overview of nickel-titanium alloys used in dentistry. Int Endod J 2000; 43: 69-76. http://dx.doi.org/10.1046/j.1365-2591.2000.00339.x.
16. Bonetti-Filho I, Esberard R, Leonardo RT, Del Rio CE. Microscopic evaluation of three endodontic files pre and post instrumentation. J Endodont 1998; 24: 461-463. http://dx.doi.org/ 10.1016/s0099-2399(98)80046-0.
17. Logsdon J, Dunlap C, Arias A, Scott R, Peters OA. Current Trends in Use and Reuse of Nickel-Titanium Engine-driven Instruments: A Survey of Endodontists in the United States. J Endodont 2020; 46, 391-396. https://doi.org/10.1016/j.joen.2019.12.011
18. Spagnuolo G, Ametrano G, D’Anto V, Rengo C, Simeone M, Riccitiello F, Amato M. Effect of autoclaving on the surfaces of TiN -coated and conventional nickel-titanium rotary instruments. Int Endod J 2012; 45:1148-55. http://dx.doi.org/10.1111/j.1365-2591.2012.02088.x.
19. Casella G, Rosalbino F. Corrosion behaviour of NiTi endodontic instruments. Corros Eng Sci Techn 2011; 46: 521-523. http://doi.org/10.1179/147842209X12559428167445
Published
2025/12/22
Section
Originalni rad / Original article