METODE PROCENE DIMENZIONALNE STABILNOSTI ELASTOMERNIH MATERIJALA ZA UZIMANJE OTISAKA NAKON DEZINFEKCIJE: PREGLED LITERATURE

  • Enis Sabanov Univerzitetski Stomatoloski Klinicki centar "Sv Pantelejmon" Skopje, Severna Makedonija
  • Marija Dostinova PZU “ Protetika Petkovi” Skoplje, Severna Makedonija
  • Saso Elencevski Clinic for dental prosthetics University Clinical Center "Ss Pantelejmon" Skopje, North Macedonia ,University “Ss Cyril and Methodius”, Faculty of Dentistry,Skopje,North Macedonia
  • Sanja Pancevska 1Klinika za stomatološku protetiku Univerzitetski klinički centar “Sv. Pantelejmon” Skoplje, Severna Makedonija ,Univerzitet “ Sv. Kiril I Metodij”, Stomatoloski fakultet, Skplje, Severna Makedonija
Ključne reči: elastomerni otisci, dezinfekcija, stabilnost dimenzija, ispitivanja

Sažetak


Precizni i dimenzionalno stabilni materijali za uzimanje otisaka ključni su za uzimanje dobrog otiska, ali preciznost otiska i tačnost reprodukcije zavise i od još nekoliko faktora; jedan od najvažnijih je način dezinfekcije i njeno trajanje. Svrha ovog preglednog rada bila je da se sagledaju različite preporučene procedure za dezinfekciju elastomernih dentalnih otisaka i najčešće korišćene metode, kao i oprema za ocenu njihove dimenzionalne stabilnosti nakon dezinfekcije. Za potrebe ovog istraživanja izvršili smo elektronsku pretragu MEDLINE (PubMed) i baze podataka (Google Scholar) i pregledali smo članke objavljene u periodu od 2011. do 2022. godine. Odabrano je 39 najaktuelnijih i relevantnih studija fokusiranih na dezinfekciju elastomernih materijala za uzimanje otisaka, te na metode i opremu primenjene pri proceni stabilnosti dimenzija elastomernih otisaka nakon njihove dezinfekcije. Naša analiza je pokazala da su najčešće korišćeni dezinfekcioni materijali gluteraldehid i natrijum-hipohlorit. Dezinfekcija je obično trajala od deset do petnaest minuta. Kada je reč o metodama korišćenim za procenu dimenzionalnih promena, zapaženo je da je 26 autora od njih 39 najčešće upotrebljavalo mikroskop. Pregledom literature potvrđena je nestandardizacija metodologija primenjenih u istraživanju i njihova velika raznovrsnost. 

Reference

Abdelhameed SA, Shalaby YA, El Halawani MT. Comparative assessment of dimensional stability of addition silicone impression under the effect of disinfection materials. Alexandria Dental Journal 2021;47(2):140-6. [CrossRef]

Ahila S, Subramaniam E. Comparative evaluation of dimensional stability and surface quality of gypsum casts retrieved from disinfected addition silicone impressions at various time intervals: an in vitro study. J Dent Oral Hyg 2012;4(4):34-43.

Ahila SC, Thulasingam C. Effect of disinfection on gypsumcasts retrieved from addition and condensation silicone impressiondisinfected by immersion and spray methods. SRM J Res Dent Sci 2014;5(3):163–9. [CrossRef]

Alam M, Amini P, Ghaffarpasand A, Dalooei NK, Hadi A, Abbasi K. Effect of Surfosept and Deconex® 53 Disinfectant Agents on the Accuracy and Dimensional Stability of Panasil Dental Impression Materials: An Experimental Study. Evidence-Based Complementary and Alternative Medicine 2021;2021:1248531. [CrossRef][PubMed]

Almuraikhi T. Effect of Disinfectants on Dimensional Stability of Two Elastomeric Impression Materials: An In Vitro Study. World J Dent 2022;13(5):489–92. [CrossRef]

Asopa SJ, Padiyar UN, Verma S, Suri P, Somayaji NS, Radhakrishnan IC. Effect of heat sterilization and chemical method of sterilization on the polyvinyl siloxane impression material. A comparative study. J Family Med Prim Care 2020;9(3):1348-534. [CrossRef][PubMed]

Azevedo MJ, Correia I, Portela A, Sampaio-Maia B. A simple and effective method for addition silicone impression disinfection. J Adv Prosthodont 2019;11(3):155-61. [CrossRef][PubMed]

Carvalhal CI, Mello JA, Correr AB, Sinhoreti MA. Dimensional change of elastomeric materials after immersion in disinfectant solutions for different times. J Contemp Dent Pract 2011;12(4):252-8. [CrossRef][PubMed]

Čatović A, Komar D, Čatić A, editors. Klinička fiksna protetika I – krunice. Zagreb: Medicinska naklada; 2015.

Demajo JK, Cassar V, Farrugia C, Millan-Sango D, Sammut C, Valdramidis V, et al. Effectiveness of Disinfectants on Antimicrobial and Physical Properties of Dental Impression Materials. Int J Prosth 2016;29(1):63-7. [CrossRef][PubMed]

Duseja S, Shah RJ, Shah DS, Duseja S. Dimensional measurement accuracy of recent polyether and addition silicone monophase impression materials after immersion in various disinfectants: An in vitro study. Int J Health Biomed Res 2014;2:87–7.

Ghasemi E, Fathi AH, Parvizinia S. Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials. J Iran Dent Assoc 2019;31(3):169-76. [CrossRef]

Godbole SR, Dahane TM, Patidar NA, Nimonkar SV. "Evaluation of the Effect of Ultraviolet Disinfection on Dimensional Stability of the Polyvinyl Silioxane Impressions." an in-Vitro Study. J Clin Diagn Res 2014;8(9):73-6. [CrossRef][PubMed]

Goel K, Gupta R, Solanki J, Nayak M. A comparative study between microwave irradiation and sodium hypochlorite chemical disinfection: a prosthodontic view. J Clin Diagn Res 2014;8(4)42-6. [CrossRef][PubMed]

Guiraldo RD, Berger SB, Punhagui MF, Moretto TS, Lopes MB, Gonini-Júnior A, et al. Influence of chloramine-T disinfection on elastomeric impression stability. Eur J Dent 2018;12(2):232-6. [CrossRef][PubMed]

Guiraldo RD, Berger SB, Sigueira RM, Grandi VH, Lopes MB, Gonini-Júnior A, et al. Surface detail reproduction and dimensional accuracy of molds: influence of disinfectant solutions and elastomeric impression materials. Acta Odontol Latinoam 2017;30(1):13-8. [PubMed]

Hiraguchi H, Kaketani M, Hirose H , Kikuchi H, Yoneyama T. Dimensional changes in stone casts resulting from long-term immersion of addition-type silicone rubber impressions in disinfectant solutions. Dental Materials Journal 2013;32(3);361-6. [CrossRef][PubMed]

Hiraguchi, H, Iwasaki Y, Iwasaki E, Kikuchi H, Hirose, H, Yoneyama T. Dimensional changes in stone models simulating full crown preparations with adjacent teeth resulting from long-term immersion of medium-viscosity addition-type silicone rubber impressions in disinfectant solutions. Dent Mater J 2015;34(1):48-53. [CrossRef][PubMed]

Kamble SS, Khandeparker RV, Somasundaram P, Raghav S, Babaji RP, Varghese TJ. Comparative Evaluation of Dimensional Accuracy of Elastomeric Impression Materials when Treated with Autoclave, Microwave and Chemical Disinfection. Journal of International Oral Health 2015;7(9):22-4. [PubMed]

Khatri M, Mantri SS, Deogade SC, Bhasin A, Mantri S, Khatri N, et al. Effect of Chemical Disinfection on Surface Detail Reproduction and Dimensional Stability of a New Vinyl Polyether Silicone Elastomeric Impression Material.Contemporary Clinical Dentistry 2020;11(1):10-4. [CrossRef][PubMed]

Khinnavar PK, Kumar BH, NandeeshwarDB. An in vitro study to evaluate the effect on dimensional changes of elastomers during cold sterilization. The Journal of Indian Prost Society 2015;15(2):131-7. [CrossRef][PubMed]

Kuei-ling Hsu. 3D cone-beam C.T. imaging used to determine theeffect of disinfection protocols on the dimensional stability of full arch impressions. Saudi Dent J 2021;33(7):453–61. [CrossRef][PubMed]

Mahalakshmi AS, Jeyapalan V, Mahadevan V, Krishnan CH, Azhagarasan NS, Ramakrishnan H. Comparative evaluation of the effect of electrolyzed oxidizing water on surface detail reproduction, dimensional stability and Surface texture of poly vinyl siloxane impressions. J Indian Prosthodontic Soc 2019;19(1):33–41. [CrossRef][PubMed]

Martins F, Branco P, Reis J, Navarro B, Mauricio P. Dimensional stability of two impression materials after a 6-month storage period. Acta Biomaterialia Odontologica Scandinavica 2017;3(1):84-91. [CrossRef][PubMed]

Mehulić K, editor. Dentalni materijali. Zagreb: Medicinska naklada; 2017.

Millar BJ, Deb S. Effect of Autoclave Sterilisation on the Dimensional Stability and Tear Strength of Three Silicone Impression Materials. Open Journal of Stomatology 2014;4(12):518-26. [CrossRef]

Mohd NR, Ros A, Omar RA, Etajuri EA. Dimensional Stability of Elastomeric Impression Material After Disinfection Via Immersion and Microwave Irradiation. The Open Dentistry Journal 2021;15:658-63. [CrossRef]

Nandini Y, Vinitha KB, Manvi S, Smitha M. Comparison of Dimensional Accuracy of Four Different Die Materials before and after Disinfection of the Impression: An in vitro Study. J Contemp Dent Pract 2013;14(4):668-74. [CrossRef][PubMed]

Nassar U, Ava K. Surface Detail Reproduction and Effect of Disinfectant and Long-Term Storage on the Dimensional Stability of a Novel Vinyl Polyether Silicone Impression Material Ј Prosthodont 2015;24(6):494-8. [CrossRef][PubMed]

Nassar U, Flores-Mir C, Heo G, Torrealba Y. The effect of prolonged storage and disinfection on the dimensional stability of 5 vinyl polyether silicone impression materials. J Adv Prosthodont 2017;9(3):182-7. [CrossRef][PubMed]

Nimonkar SV, Belkhode VM, Godbole SR, Nimonkar PV, Dahane T, Sathe S. Comparative evaluation of the effect of chemical disinfectants and ultraviolet disinfection on dimensional stability of the polyvinyl siloxane impressions. J Int Soc Prev Community Dent 2019;9(2):152-8. [CrossRef][PubMed]

Özdemir O, Pekince KA. Evaluation of the effect of storage time and disinfectant solutions on the dimensional accuracy of impression materials with digital radiography. Dent Med Probl 2019;56(1):67-74. [CrossRef][PubMed]

Pal PK, Kamble SS, Chaurasia RR, Chaurasia VR, Tiwari S, Bansal D. Evaluation of different disinfactants on dimensional accuracy and surface quality of type IV gypsum casts retrieved from elastomeric impression materials. J Int Oral Health 2014;6(3):77-81. [PubMed]

Samra RK, Bhide SV. Comparative evaluation of dimensional stability of impression materials from developing countries and developed countries after disinfection with different immersion disinfectant systems and ultraviolet chamber. Saudi Dent J 2018;30(2):125-41. [CrossRef][PubMed]

Sana M, Sharma S, Jyothi J, Rizwanulla R, Mouli YC. Evaluation of surface quality and dimensional accuracy of Elastomeric impression materials after various disinfections protocols. International Journal of Scientific research 2021;10(8):60-2. [CrossRef]

Sinobad T, Obradovic-Djuricic K, Nikolic Z, Dodic S, Lazic L, Vladimir Sinobad, et al. The effect of disinfectants on dimensional stability of addition and condensation silicone impressions. Vojnosanit Pregl 2014;71(3):251–8. [CrossRef][PubMed]

Sinobad T. Evaluacija fotometriskih u ispitivanju dimenzionalne stabilnosti elastomernih otisnih materijala. [Doktorska disertacija]. Beograd: Univerzitet Beograd; 2016.

Soganci G, Cinar D, Caglar A, Yagi A. 3D evaluation of the effect of disinfectants on dimensional accuracy and stability of two elastomeric impression materials. Dent Mater J 2018;37(4):675-84. [CrossRef][PubMed]

Surendra GP, Anjum A, Satish Babu CL, Shett S. Evaluation of Dimensional Stability of Autoclavable Elastomeric Impression Material. J Indian Prosthodontic Soc 2011;11(1):63–6. [CrossRef][PubMed]

Thota KK, Jasthi S, Ravuri R, Tella S. A comparative evaluation of the dimensional stability of three different elastomeric impression materials after autoclaving - an invitro study. J Clin Diagn Res 2014;8(10):48-50. [CrossRef][PubMed]

Ud Din S, Sajid M, Saeed A, Chaudhary FA, Alam MK, Sarfraz J, et al. Dimensional changes of commercial and novel polyvinyl siloxane impression materials following sodium hypochlorite disinfection. Peer J 2022;10:e12812. [CrossRef][PubMed]

Vrbova R, Bradna P, Bartos M, Roubickova A. The effect of disinfectants on the accuracy, quality and surface structure of impression materials and gypsum casts: A comparative study using light microscopy, scanning electron microscopy and micro computed tomography. Dent Mater J 2020;39(3):500-8. [CrossRef][PubMed]

Wezgowiec J, Paradowska-Stolarz A , Malysa A, Orzeszek S, Seweryn P,Wieckiewicz M. Effects of Various Disinfection Methods on the Material Properties of Silicone Dental Impressions of Different Types and Viscosities. Int J Mol Sci 2022;23:10859. [CrossRef][PubMed]

Yousief SA, Alzahrani KT, Alhuwairini SM, Alharbi FY, Eissa DA, Almojaddidi SM, et al. The Effects of Chemical Disinfection on Dimensional Stability among Different Type of Impression Addition Silicon Materials. International Journal of Innovative Research in Medical Science 2020;5(12):645–9. [CrossRef]

Objavljeno
2024/10/31
Rubrika
Pregledni rad