Abstract


Background/Aim: There is a need of investigation of high frequency of the cases of ABO discrepancy revealed by forward and reverse typing. The aim of the study was to reveal optimal methods for detection of weak subgroups of group A and B antigens on erythrocytes.

Methods: Sixteen persons with A blood group and anti-B antibody adsorbing ability (weak Bel, Bm and B3 antigens), 5 persons with B blood group and anti-A antibody adsorbing ability (weak Ax antigen) and 2 persons with O blood group and anti-B antibody adsorbing ability (weak Bel antigen) were investigated as the cases of type II-III of ABO discrepancy and weak B antigen. Liquid chromatography, agglutination, inhibition of agglutination and adsorption reactions at 4 °C and 37 °C with prolonged incubation (12 hours) were used in the study.

Results: The persons with A blood group revealed by forward typing at 4 °C and O blood group detected by reverse typing at 37 °C showed the ability of the erythrocytes to adsorb anti-B antibody. The persons with B blood group revealed by forward typing with presence of anti-B antibodies reactive at 37 °C showed the ability of erythrocytes to adsorb anti-A antibody. Prolonged incubation at reverse typing, adsorption-elution tests, inhibition of haemagglutination and liquid chromatography were used to define blood group specificity.

Conclusion: Prolonged incubation during reverse typing at 4 °C and 37 °C, adsorption at 4 °C, heat elution and liquid chromatography might help to detect blood group type in cases of type II-III of ABO discrepancy.

References

Chiaroni J, Legrand D, Dettori I, Ferrera V. Analysis of ABO discrepancies occurring in 35 French hospitals. Transfusion 2004;44(6):860-4.

Saqlain N, Mazher N, Fateen T, Parveen A. ABO discrepancy in pediatric lymphomas and solid organ tumors. TPMJ 2022;29(11):1662-6.

Meny GM. Recognizing and resolving ABO discrepancies. Immunohematology 2017;33(2):76-81.

Bianco T, Farmer BJ, Sage RE, Dobrovic A. Loss of red cell A, B, and H antigens is frequent in myeloid malignancies. Blood 2001; 97(11):36333639. DOI: 10.1182/blood.v97.11.3633.

Vadivelu MK, Damodaran S, Solomon J, Rajaseharan A. Distribution of ABO blood groups in acute leukaemias and lymphomas. Ann Hematol 2004; 83(9):584-7.

Itzkowitz SH, Yuan M, Ferrell LD, Ratcliffe RM, Chung YS, Satake K, et al. Cancer-associated alterations of blood group antigen expression in the human pancreas. J Natl Cancer Inst 1987 Sep;79(3):425-34.

Kim MH, Choi MJ, Kim HO. Analysis of ABO discrepancy (82 cases). Korean J Clin Pathol 1991;11(2):493-9.

Breimer ME, Mölne J, Nordén G, Rydberg L, Thiel G, Svalander CT. Blood group A and B antigen expression in human kidneys correlated to A1/A2/B, Lewis, and secretor status. Transplantation 2006 Aug 27;82(4):479-85.

Chun S, Ryu MR, Cha SY, Seo JY, Cho D. ABO mistyping of cis-AB blood group by the automated microplate technique. Transfus Med Hemother 2018;45:5–10.

Pagliaro P. Errors in transfusion medicine are not only misidentifications of the recipient, but also pre-analytical and analytical errors. Clin Chem Lab Med 2010;48:1053–4.

Shin E, Kim H, Hur M, Lee H, Sohn IS, Park KU, Seo DH. Cis-AB showing discrepant results across different automated and manual methods: a case report and review of the literature. Clin Chem Lab Med 2023 Feb 24;61(8):e156-e9.

Kaur G, Basu S, Kaur P, Kaur R. Clinically significant anti M antibodies – a report of two cases. Transfus Apher Sci 2012;47:259-61.

Hermelin D, Zhang D, Blackall D. Resolution of an unexpected ABO typing discrepancy in a 9-month-old patient with juvenile myelomonocytic leukemia. Clinical Case Reports 2020;8(12):2358-60.

Trongratsameethong A, Somhom S, Chawachat J, Wita R, Anukul N, Sirikul C. Ontology for blood group phenotyping and ABO discrepancy screening. 18th International JCSSE, Lampang, Thailand 2021, pp. 1-6. doi: 10.1109/JCSSE53117.2021.9493808.

Cohn CS, Delaney M, Johnson ST, Katz LM, eds. Technical manual, 21st edition. Bethesda, MD: AABB, 2023.

Jalali SF, Gudarzi S, Amirizadeh N, Mirzaeeian F, Oodi A. Analysis of ABO subgroups which result in ABO discrepancies in Iranian blood donors. Transfus Apher Sci 2023 Apr;62(2):103586. doi: 10.1016/j.transci.2022.103586.

Brecher ME, ed. Technical manual. 14th ed. Bethesda, MD: American Association of Blood Banks, 2002: 667 pp.

Wasnik M, Lahare S, Tejaswani P. Blood group discrepancy in a whole blood donor with weak AB. Cureus 2023 Jun 22;15(6):e40834. doi: 10.7759/cureus.40834.

Brecher ME, ed. Technical manual. 14th ed. Bethesda, MD: American Association of Blood Banks, 2014:842 pp.

Park TS, Seung-Hwan OH, Choi JC, Kim HH, Park JH, Lee EY, et al. A case of agammaglobulinemia detected by ABO discrepancy in a 13-year-old girl. Korean J Lab Med 2002;22(5):364-6.

Hermelin D, Zhang D, Blackall D. Resolution of an unexpected ABO typing discrepancy in a 9-month-old patient with juvenile myelomonocytic leukemia. Clin Case Rep 2020 Jul 15;8(12):2358-60.

Park J, Dong DW, Park SY, Shin S. Combined group I and III ABO discrepancies in multiple myeloma with IgG-Lambda type: a case report. Med Princ Pract 2017;26 (1):9092. doi:10.1159/000450579.

Miola MP, Tharsis de Oliveira T, Guimarães AAG, Mattos LD. ABO discrepancy resolution in two patients with acute myeloid leukemia presenting the transient weak expression of A antigen. Hematol Transfus Cell Ther 2022 Mar 11:S2531-1379(22)00037-2. doi: 10.1016/j.htct.2022.01.015.

Khan MN, Khan TA, Ahmed Z. Discrepancy in ABO blood grouping. J Coll Physicians Surg Pak 2013;23(8):590-2.

Ramya C, Renuka IV, Rizwana S, Sowjanya KK. Type III ABO discrepancy aiding in diagnosis of multiple myeloma. IP J Diagn Pathol Oncol 2020;5(2):220-2.

Nepal B, Shrestha B, Mahat R, Adhikari A. Acquired B antigen in ABO blood group system: Non-secretor group ’A1’ subtype, Rh positive with auto antibodies in a patient with urinary tract infection with E. coli. Grande Medical J 2019;1(1),44–7.

Dewi DM, Metwally T. Adsorption technique in pre-transfusion testing for patients with warm type autoimmune hemolytic anemia. Egypt J Immunol 2017;24(2):47-51.

Mohammadi S, Moghaddam M, Babahajian S, Karimian M S, Ferdowsi S. Discrepancy in ABO blood grouping in a blood donor: a case report. IJBC 2018;10(2):61-3.

Subramaniyan R, Gaspar BL. A closer look into blood group discrepancy arising due to an underlying malignancy. Rev Bras Hematol Hemoter 2016;38(4):361363. doi: 10.1016/j.bjhh.2016.04.007.

Jung CL, Cha MK, Jun BH, Hong KS. A case of IgM deficiency with B Cell deficiency detected by ABO discrepancy in a patient with acute osteomyelitis. Ann Lab Med 2013; 33(3): 208-11.

Samarah FH, Srour MA. An unusual report of anti-N antibody presenting as ABO discrepancy in an old female patient in Palestine. Asian J Transfus Sci 2019;13:140-1.

Matthew M, Behan KJ. ABO discrepancy and hemolytic anemia post liver transplant due to passenger lymphocyte syndrome. Lab Med 2011;42(3):137–9.

Routray SS, Prakash S, Ray GK, Mukherjee S. Detection of ABO discrepancy in a case of coronary artery disease by conventional tube technique: a miss by column agglutination technology. J Lab Physicians 2022;14:87-9.

Heal JM, Masel D, Rowe JM, Blumberg N. Circulating immune complexes involving the ABO system after platelet transfusion. Br J Haematol 1993;85(3):566-72.

Heal JM, Masel D, Blumberg N. Interaction of platelet fc and complement receptors with circulating immune complexes involving the AB0 system. Vox Sang 1996;71(4):205-11.

Qiu H, Wang X, Shao Y. Forward and reverse typing discrepancy and crossmatch incompatibility of ABO blood groups: cause analysis and treatment. Hematology 2023;28:1. DOI: 10.1080/16078454.2023.2240146.

Published
2023/12/21
Section
Professional article