Korist od primene ultrazvuka za procenu odgovora bolesnika sa septičkim šokom na nadoknadu volumena

  • Hao He The Fourth Hospital of Changsha, Department of Critical Care Medicine, Changsha, Hunan Province, China
  • Nifang Pan Changshu Hospital Affiliated to Soochow University, Changshu No. 1 People's Hospital, Changshu, Jiangsu Province, China
  • Xiaoyong Zhou Center of Emergency and Intensive Care Unit, Shanghai, China
Ključne reči: krv, volumen, hemodinamika, monitoring, infuzije, intravenske, rastvor, fiziološki, šok, septički, ultrasonografija

Sažetak


Uvod/Cilj. Septički šok (SŠ) je komplikacija koja može nastati kao posledica infekcije. S obzirom na to da je efektivni cirkulatorni volumen krvi od velike važnosti u ovim slučajevima, kontinuirano  praćenje parametara volumena krvi je ključno. Cilj ovog rada je bio da se istraži značaj primene ultrazvuka za procenu odgovora na nadokandu volumena (volume responsiveness – VR) kod bolesnika sa SŠ. Metode. Odabrano je ukupno 102 bolesnika sa SŠ. Urađen je test volumenskog opterećenja (volume load – VL), i na osnovu rezultata testa, bolesnici su bili podeljeni u dve grupe. Jednu grupu činili su bolesnici koji su pokazali odgovor (response - R) na VL testu (grupa R); kod njih je povećanje udarnog volumena (stroke volume-SV) (ΔSV) bilo ≥ 15% posle VL testa. Drugu grupu (non-response – NR) činili su bolesnici kod kojih je ΔSV bio < 15% posle VL testa. U grupama je bilo 54 bolesnika (R) i 48 bolesnika (NR). Ispitivani hemodinamički parametri upoređivani su pre i posle VL testa. Korelacija između ΔSV i svakog pojedinačnog hemodinamičkog indeksa ispitivana je Pirsonovom analizom, a za određene parametre korišćene su ROC krive. Rezultati. Pre VL testa, veće vrednosti u grupi R u odnosu na grupu NR (p < 0,05) imali su sledeći indeksi: rastegljivost retro-hepatične (RH) donje šuplje vene [inferior vena cava (IVC)] (ΔRHIVC1), respiratorna varijacija RHIVC (ΔRHIVC2), respiratorna varijacija najveće brzine protoka krvi u aorti (ΔVpeakAO), respiratorna varijacija najveće brzine protoka krvi u brahijalnoj arteriji (BA) (ΔVpeakBA) i respiratorna varijacija najveće brzine protoka krvi u zajedničkoj femoralnoj arteriji [common femoral artery (CFA)](ΔVpeakCFA). Frekvencija srca (FS), srednji arterijski pritisak (SAP) i centralni venski pritisak (CVP) su imali slične vrednosti (p > 0,05) u obe grupe. Nakon VL testa, grupa R imala je značajno smanjenje vrednosti FS i indeksa ΔRHIVC1, ΔRHIVC2, ΔVpeakAO, ΔVpeakBA i ΔVpeakCFA, a povećanje vrednosti SAP i CVP (p < 0,05). Grupa NR imala je značajno smanjen CVP (p < 0,05), a nisu primećene značajne promene u vrednostima ostalih indeksa. Indeksi ΔRHIVC1, ΔRHIVC2, ΔVpeakAO, ΔVpeakBA i ΔVpeakCFA bili su u značajnoj korelaciji sa ΔSV (r = 0,589, r = 0,647, r = 0,697, r = 0,621, r = 0,766, redom; p < 0.05 ), ali nije bilo korelacije između CVP i ΔSV (r = -0,345; p > 0,05). Površine ispod ROC krive [areas under the curve (AUC)] za indekse ΔRHIVC1, ΔRHIVC2, ΔVpeakAO, ΔVpeakBA i ΔVpeakCFA, koji su korišćeni za predviđanje VR, iznosile su 0,839, 0,858, 0,878, 0,916 i 0,921 redom, i bile su značajno veće od AUC za CVP (0,691), što je ukazivalo da su indeksi ΔRHIVC1, ΔRHIVC2, ΔVpeakAO, ΔVpeakBA i ΔVpeakCFA imali viši nivo osetljivosti i specifičnosti u poređenju sa CVP. Zaključak. Ultrazvučnim praćenjem indeksa ΔRHIVC1, ΔRHIVC2, ΔVpeakAO, ΔVpeakBA i ΔVpeakCFA može se preciznije proceniti VR kod bolesnika sa SŠ.

Reference

1.      Bataille B, de Selle J, Moussot PE, Marty P, Silva S, Cocquet P. Machine learning methods to improve bedside fluid responsiveness prediction in severe sepsis or septic shock: an observational study. Br J Anaesth 2021; 126(4): 826‒34.

2.      Zhuang Y, Dai L, Cheng L, Lu J, Pei Y, Wang J. Inferior vena cava diameter combined with lung ultrasound B-line score to guide fluid resuscitation in patients with septic shock. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue 2020; 32(11): 1356‒60. (Chinese)

3.      Chambers KA, Park AY, Banuelos RC, Darger BF, Akkanti BH, Macaluso A, et al. Outcomes of severe sepsis and septic shock patients after stratification by initial lactate value. World J Emerg Med 2018; 9(2): 113‒7.

4.      Zuccari S, Damiani E, Domizi R, Scorcella C, D'Arezzo M, Carsetti A, et al. Changes in Cytokines, Haemodynamics and Microcirculation in Patients with Sepsis/ Septic Shock Undergoing Continuous Renal Replacement Therapy and Blood Purification with CytoSorb. Blood Purif 2020; 49(1‒2): 107‒13.

5.      Lu N, Jiang L, Zhu B, Han W, Zhao Y, Shi Y, et al. Variability of peripheral arterial peak velocity predicts fluid responsiveness in patients with septic shock. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue 2018; 30(3): 224‒9. (Chinese)

6.      Corradi F, Via G, Tavazzi G. What's new in ultrasound-based assessment of organ perfusion in the critically ill: expanding the bedside clinical monitoring window for hypoperfusion in shock. Intensive Care Med 2020; 46(4): 775‒9.

7.      Airapetian N, Maizel J, Alyamani O, Mahjoub Y, Lorne E, Levrard M, et al. Does inferior vena cava respiratory variability predict fluid responsiveness in spontaneously breathing patients? Crit Care 2015; 19: 400.

8.      Bughrara N, Diaz-Gomez JL, Pustavoitau A. Perioperative Management of Patients with Sepsis and Septic Shock, Part II: Ultrasound Support for Resuscitation. Anesthesiol Clin 2020; 38(1): 123‒34.

9.      Rhodes A, Evans LE, Alhazzani W, Levy MM, Antonelli M, Ferrer R, et al. Surviving Sepsis Campaign: International Guidelines for Management of Sepsis and Septic Shock: 2016. Intensive Care Med 2017; 43(3): 304‒77.

10.   Mojoli F, Bouhemad B, Mongodi S, Lichtenstein D. Lung Ultrasound for Critically Ill Patients. Am J Respir Crit Care Med 2019; 199(6): 701‒14.

11.   Qi F, Cao L, Zhang LL, Wang Y, Guo WW, Li F. The predictive value of cardiopulmonary interaction monitoring technology on volume responsiveness in septic shock patients. Chin J Emerg Med 2019; 28: 869‒74. (Chinese).

12.   Vieillard-Baron A, Prigent A, Repessé X, Goudelin M, Prat G, Evrard B, et al. Right ventricular failure in septic shock: characterization, incidence and impact on fluid responsiveness. Crit Care 2020; 24(1): 630.

13.   Kim JS, Kim M, Kim YJ, Ryoo SM, Sohn CH, Ahn S, et al. Troponin Testing for Assessing Sepsis-Induced Myocardial Dysfunction in Patients with SS. J Clin Med 2019; 8(2): 239.

14.   Qi B, Yang WB, Zhang H, Li GZ, Cai JJ, Zhang WZ, et al. Clinical application of inferior vena cava inspiratory collapsibility in early goal-directed therapy of septic shock. Chin J Resp Crit Care Med 2020; 19: 246‒50. (Chinese)

15.   Si X, Xu H, Liu Z, Wu J, Cao D, Chen J, et al. Does Respiratory Variation in Inferior Vena Cava Diameter Predict Fluid Responsiveness in Mechanically Ventilated Patients? A Systematic Review and Meta-analysis. Anesth Analg 2018; 127(5): 1157‒64.

16.   Huan C, Lu C, Song B, Li PC, Ren HS, Chu YF, et al. The shape change index (SCI) of inferior vena cava (IVC) measuring by transabdominal ultrasound to predict the presence of septic shock in intensive care unit (ICU) patients. Eur Rev Med Pharmacol Sci 2019; 23(6): 2505‒12.

17.   Shrestha GS, Srinivasan S. Role of Point-of-Care Ultrasonography for the Management of Sepsis and septic shock. Rev Recent Clin Trials 2018; 13(4): 243‒51.

18.   Pei Y, Yang Y, Feng Y, He S, Zhou J, Jiang H, et al. Diagnostic accuracy of artery peak velocity variation measured by bedside real-time ultrasound for prediction of fluid responsiveness: a Meta-analysis. Zhonghua Wei Zhong Bing Ji Jiu Yi Xue 2020; 32: 99‒105. (Chinese)

19.   Kim JH, Kim WY, Oh J, Kang H, Lim TH, Ko BS. Association of inferior vena cava diameter ratio measured on computed tomography scans with the outcome of patients with septic shock. Medicine (Baltimore) 2020; 99(43): e22880.

20.   Seif D, Perera P, Mailhot T, Riley D, Mandavia D. Bedside ultrasound in resuscitation and the rapid ultrasound in shock protocol. Crit Care Res Pract 2012; 2012: 503254.

Objavljeno
2023/05/31
Rubrika
Originalni članak