Uticaj dezinficijenasa na dimenzionalnu stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona

  • Tamara Sinobad Clinic of Dental Prosthetic, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia
  • Kosovka Obradović-Djuričić Clinic of Dental Prosthetic, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia
  • Zoran Nikolić Faculty of Physics, University of Belgrade, Belgrade, Serbia
  • Slobodan Dodić Clinic of Dental Prosthetic, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia
  • Vojkan Lazić Clinic of Dental Prosthetic, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia
  • Vladimir Sinobad Clinic of Maxillofacial Surgery, Faculty of Dental Medicine, University of Belgrade, Belgrade, Serbia
  • Aleksandra Jesenko-Rokvić Faculty of Pharmacy, University of Belgrade, Belgrade, Serbia
Ključne reči: dental impression materials||, ||stomatološki materijali za otiske, silicones||, ||silikoni, disinfectans||, ||dezinfekcija, dental prosthesis||, ||zubna proteza,

Sažetak


Uvod/Cilj. Dimenzionalna stabilnost i preciznost otiska posle hemijske dezinfekcije potapanjem u dezinficijens predstavljaju osnovu za preciznost definitivnih zubnih nadoknada. Cilj ovog istraživanja bio je da se proceni dimenzionalna stabilnost otisaka izrađenih od adicionih i kondenzacionih silikona posle dezinfekcije u antimikrobnim rastvorima. Metode. Napravljen je uzorak od 120 otisaka, dobijenih otiskivanjem modela gornje vilice sa ispreparisanim zubima za metalokeramičke krune. Od otisnih materijala korišćena su dva kondenzaciona silikona (Oranwash L – Zhermack i Xantopren L Blue – Heraeus Kulzer) i dva adiciona silikona (Elite H-D + regular body – Zhermack i Flexitime correct flow – Heraeus Kulzer). Odmah po odvajanju od modela, otisci su potopljeni u odgovarajući dezinficijens (glutaraldehid, benzalkonijum-hlorid – Sterigum i 5,25% NaOCl) u trajanju od 10 min. Kontrolnu grupu činili su uzorci koji nisu tretirani dezinficijensom. Uzastopna merenja istovetnih otisaka vršena su pomoću fotoaparata Canon G9 (12 megapiksela, 2 fps, 6 ´ / 24 ´), a automatizovana sa računara Asus VX 2R Lamborghini-Intel C2D 2,4 GHz, korišćenjem opcija softverskog paketa Remote Capture tako da su dobijene vremenske serije fotografija istog otiska. Rezultati. Utvrđene su izražene dimenzionalne promene svih uzoraka kako u funkciji vremena tako i u funkciji primenjenog dezinficijensa. Rezultati pokazuju postojanje značajnih razlika dimenzionalnih promena između grupe kondenzacionih silikona i grupe adicionih silikona za isto vreme i isti primenjeni dezinficijens (p = 0,026, F = 3,95). Zaključak. Najveće dimenzionalne promene otisaka uzetih adicionim i kondenzacionim silikonima beleže se u prvom satu po odvajanju sa modela.

Reference

Stamenkovic D, Obradovic-Ðuricic K, Ivanovic V, Vulicevic ZR, Markovic D, Todorovic A, et al. Dental Materials. Belgrade: Uni-versity of Belgrade, School of Dental Medicine; 2009. (Serbian)

Hamalian TA, Nasr E, Chidiac JJ. Impression Materials in Fixed Prosthodontics: Influence of Choice on Clinical Procedure. J Prosthodont 2011; 20(2): 153−60.

Estafanous EW, Palenik CJ, Platt JA. Disinfection of Bacterially Contaminated Hydrophilic PVS Impression Materials. J Pros-thodont 2012; 21(1): 16−21.

Surendra GP, Anjum A, Babu CLS, Shetty S. Evaluation of dimensional stability of autoclavable elastomeric impression material. J Indian Prosthodont Soc 2011; 11(1): 63−6.

Stober T, Johnson GH, Schmitter M. Accuracy of the newly for-mulated vinyl siloxanether elastomeric impression material. J Prosthet Dent 2010; 103(4): 228−39.

Lucas MG, Arioli JN, Nogueira SS, Batista AU, Pereira RD. Effect of Incorporation of Disinfectant Solutions on Setting Time, Linear Dimensional Stability, and Detail Reproduction in Dental Stone Casts. J Prosthodont 2009; 18(6): 521−6.

ADA Council on Scientific Affairs and ADA Council on Dental Prac-tice.Infection control recommendations for the dental office and the dental laboratory. J Am Dent Assoc 1996; 127(5): 672−80.

Kohn WG, Collins AS, Cleveland JL, Harte JA, Eklund KJ, Malvitz DM. Centers for Disease Control and Prevention (CDC). Guidelines for infection control in dental health-care settings--2003. MMWR Recomm Rep 2003; 52(RR−17): 1−61.

Almortadi N, Chadwick RG. Disinfection of dental impressions - compliance to accepted standards. Br Dent J 2010; 209(12): 607−11.

Giammanco GM, Melilli D, Rallo A, Pecorella S, Mammina C, Pizzo G. Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions. New Microbiol 2009; 32(2): 167−72.

Lepe X, Johnson GH. Accuracy of polyether and addition sili-cone after long-term immersion disinfection. J Prosthet Dent 1997; 78(3): 245−9.

Shillingburg H, Hobo S, Whitsett L, Jacobi R, Brachett S. Funda-mental of Fixed Prosthodontics. 3rd ed. Chicago: Quintes-sence Publishing Co Inc; 1997.

ISO 4823: 2000. Dentistry–elastomeric impression materials. International Organization for Standardization. Geneva, Swit-zerland, 2000. Available from: http://www.iso.ch/iso/en/prods-services/ISOstore/store.html. [accessed 2004 June 25].

Corso M, Abanomy A, Di Canzio J, Zurakowski D, Morgano SM. The effect of temperature changes on the dimensional stability of polyvinyl siloxane and polyether impression materials. J Prost Dent 1998; 79(6): 626−31.

Jakšić Z, Vrhovac S, Panić B, Nikolić Z, Jelenković B. Upward pe-netration of grains through a granular medium. Eur Phys J E Soft Matter 2008; 27(4): 345−56.

Todorovic-Markovic B, Markovic Z, Mohai I, Nikolic Z, Farkas Z, Szepvolgyi J, et al. RF thermal plasma processing of fullerenes. J Phys D Appl Phys 2006; 39(2): 320−6.

Szépvölgyi J, Marković Z, Todorović-Marković B, Nikolić Z, Mohai I, Farkas Z, et al. Effects of Precursors and Plasma Parameters on Fullerene Synthesis in RF Thermal Plasma Reactor. Plasma Chem Plasma Proc 2006; 26(6): 597−608.

Pavlović V, Nikolić M, Nikolić Z, Branković G, Živković L, Pavlović V. Microstructural Evolution and Electric Preperties of Me-chanically Activated BaTiO3 Ceramics. J Eur Ceramic Soc 2007; 27(2−3): 575−9.

Nikolic Z. Application of numerical methods in physical cha-racterizations of polycrystal and biological systems [disserta-tion]. Belgrade: University of Belgrade, Faculty of Physics; 2006.(Serbian)

Revised American Dental Association Specification no. 19 for Non-aqueous, Elastomeric Dental Impression Materials. J Am Dent Assoc 1977; 94(4): 733−41.

Melilli D, Rallo A, Cassaro A, Pizzo G. The effect of immersion disinfection procedures on dimensional stability of two elasto-meric impression materials. J Oral Sci 2008; 50(4): 441−6.

Carvalhal C, Mello J, Sobrinho L, Correr A, Sinhoreti M. Dimen-sional change of elastomeric materials after immersion in dis-infectant solutions for different times. J Contemp Dent Pract 2011; 12(4): 252−8.

Saleh Saber F, Abolfazli N, Kohsoltani M. The effect of disinfec-tion by spray atomization on dimensional accuracy of conden-sation silicone impressions. J Dent Res Dent Clin Dent Pros-pects 2010; 4(4): 124−9.

Kronstrom MH, Johnson GH, Hompesch RW. Accuracy of a new ring-opening metathesis elastomeric dental impression material with spray and immersion disinfection. J Prosthet Dent 2010; 103(1): 23−30.

Kumar D, Madihalli A, Reedy K, Rastogi N, Pradeep N. Elastomeric impression materials:a comparison of accuracy of multiple pours. J Contemp Dent Pract 2011; 12(4): 272−8.

Thouati A, Deveaux E, Iost A, Behin P. Dimensional stability of seven elastomeric impression materials immersed in disinfec-tants. J Prosthet Dent 1996; 76(1): 8−14.

Clancy J, Scandrett F, Ettinger R. Long-term dimensional stability of three current elastomers. J Oral Rehabil 1983; 10(4): 325−33.

Quick D, Holtan J, Ross G. Use of scanning laser 3D digitizer to evaluate dimensional accuracy of dental impression materials. J Prosthet Dent 1992; 68(2): 229−35.

DeLong R, Pintado MR, Ko CC, Hodges JS, Douglas WH. Factors influencing optical 3D scanning of vinyl polysiloxane impres-sion materials. J Prosthodont 2001; 10(2): 78−85.

Shah S, Sundaram G, Bartlett D, Sherriff M. The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques. J Dent 2004; 32(8): 653−8.

Martin N, Martin MV, Jedynakiewicz NM. The dimensional stability of dental impression materials following immersion in disinfecting solutions. Dent Mater 2007; 23(6): 760−8.

Adabo GL, Zanarotti E, Fonseca RG, Cruz CA. Effect of disin-fectant agents on dimensional stability of elastomeric impres-sion materials. J Prosthet Dent 1999; 81(5): 621−4.

Matyas J, Dao N, Caputo AA, Lucatorto FM. Effects of disinfec-tants on dimensional accuracy of impression materials. J Prosthet Dent 1990; 64(1): 25−31.

Herrera SP, Merchant VA. Dimensional stability of dental im-pressions after immersion disinfection. J Am Dent Assoc 1986; 113(3): 419−22.

Michalakis K, Bakopoulou A, Hirayama H, Garefis D, Garefi P. Pre- and post-set hydrophilicity of elastomeric impression ma-terials. J Prosthodont 2007; 16(4): 238−48.

Jagger D, Vowles R, McNally L, Davis F, O Sullivan D. The Effect of a Range of Disinfectants on the Dimensional Accuracy and Stability of Some Impression Materials. Eur J Prosthodont Restor Dent 2007; 15(1): 23−8.

Wadhwani CP, Johnson GH, Lepe X, Raigrodski AJ. Accuracy of newly formulated fast-setting elastomeric impression materials. J Prosthet Dent 2005; 93(6): 530−9.

Walker MP, Rondeau M, Petrie C, Tasca A, Williams K. Surface quality and long-term dimensional stability of current elasto-meric ipression materials after disinfection: Basic science re-search. J Prosthodont 2007; 16(5): 343−51.