Glide path preparation with hand k-files and rotary pathfiles in curved root canals – an in vitro study

  • Miljan Stošić Univerzitet u Beogradu, Stomatološki fakultet
  • Katarina Geler University of Belgrade, School of dentistry
  • Violeta Petrović University of Belgrade, School of dentistry
  • Milica Jovanović - Medojević University of Belgrade, School of dentistry
Keywords: Glide path; Curved canals; Hand K-files; rotary NiTi Pathfiles

Abstract


Introduction: Preparation of glide path is an important precondition for safe use of rotary NiTi instruments during endodontic treatment.

Aim: The aim of this study was to examine the duration of glide path preparation as well as all the changes in canal morphology and canal diameter after the application of hand K-files and NiTi rotary PathFiles.

Materials and methods: This research was performed on the total of twenty Endo Training Blocks (Dentsply, Maillefer, Switzerland). The glide path was prepared using hand stainless steel K-files #10-15-20 (Dentsply, Sirona, USA) (n=10)  and NiTi rotary PathFiles (Dentsply, Sirona, Switzerland) (n=10). The time required to establish the glide path was measured with an iPhone stopwatch (Apple Inc. Cupertino, California). The images of apical segment of canals before and after glide path preparation were taken under the stereomicroscope (Boeco BSZ-405, Germany), and then  images were analyzed and processed with Scopeimage 9.0 (Teleskop, Austria). Statistical analysis was performed with Mann-Whitney test at the level of significance 5% (α=0.05).

Results: A statistically significant difference was observed in terms of the time required for glide path preparation. The mean total time for glide path preparation was significantly longer with K-files (382 ± 62) than with PathFile (200 ± 11) (p <0.05). Statistically significant difference in terms of changing the morphology of the apical part of the canal (p>0.05) was not observed. The difference in diameter of root canal was at the limit of statistical significance (p≈0.05).

Conclusion: Instrumentation with NiTi rotary PathFiles reduces the time required for glide path preparation. Preparing endodontic space for rotary instrumentation with hand K-Files and rotary PathFiles leads to similar changes in morphology of the apical segment. A slightly larger diameter of root canal was measured after preparation with the hand K-files.

Author Biographies

Violeta Petrović, University of Belgrade, School of dentistry

Prof. dr

Milica Jovanović - Medojević, University of Belgrade, School of dentistry

Ass. dr

References


  1. Schilder H. Cleaning and shaping the root canal. Dent Clin North Am. 1974;18(2):269-96.

  2. Passi S, Kaler N, Passi N. What is a glide path? The Saint's International Dental Journal. 2016;2(2):32.
    https://doi.org/10.4103/2454-3160.202220

  3. Shäfer E, Lohmann D. Efficiency of rotary nickel-titanium FlexMaster instruments compared with stainless steel hand K-Flexofile-Part1. Shaping ability in simulated curves canals. Int Endod J 2002;35:505-13.


https://doi.org/10.1046/j.1365-2591.2002.00513.x.


PMID: 12190907



  1. Gavini G, Santos MD, Caldeira CL, Machado MEL, Freire LG, Iglecias EF, Peters OA, Candeiro GTM. Nickel-titanium instruments in endodontics: a concise review of the state of the art. Braz Oral Res. 2018 Oct 18;32(suppl 1):e67.


doi: 10.1590/1807-3107bor-2018.vol32.0067.


PMID: 30365608



  1. Tewari RK, Kapoor B, Kumar A, Mishra SK, & Mukhtar-Un-Nisar Andrasbi S. Fracture of rotary nickel titanium instruments. J Oral Res Rev 2017;9:37-44.


https://doi.org/10.4103/jorr.jorr_40_16



  1. Cunha TC, Matos Fd, Paranhos LR,Bernardino Id, Moura CCG. Influence of glide path kinematics during endodontic treatment on the occurrence and intensity of intraoperative and postoperative pain: a systematic review of randomized clinical trials. BMC Oral Health. 2020;20:175.


https://doi.org/10.1186/s12903-020-01164-w



  1. Arican B, Atav A. How do Reused Glide Path Files Affect the Cyclic Fatigue Resistance?-Odovtos-Int. J. Dental Sc. 2021;23(3):98-106.


https://doi.org/ 10.15517/IJDS.2021.47503


PMid: 12657152



  1. West JD. The endodontic Glidepath: 'Secret to rotary safety'. Dent Today. 2010;29(9):86, 88, 90-3.


PMid:20973422



  1. Abu-Tahun IH, Kwak SW, Ha J-H, Sigurdsson A, Kayahan MB, Kim H-C. Effective Establishment of Glide-Path to Reduce Torsional Stress during Nickel-Titanium Rotary Instrumentation. Materials (Basel). 2019;12(3):E493.
    https://doi.org/10.3390/ma12030493
    PMid:30764565 PMCid:PMC6384996

  2. Kwak SW, Ha J-H, Cheung GS-P, Kim H-C, Kim SK. Effect of the Glide path Establishment on the Torque Generation to the Files during Instrumentation: An In Vitro Measurement. J Endod. 2018;44(3):496-500.
    https://doi.org/10.1016/j.joen.2017.09.016
    PMid:29203073

  3. Plotino G, Nagendrababu V, Bukiet F, Grande NM, Veettil SK, De-Deus G, Aly Ahmed HM. Influence of Negotiation, Glide Path, and Preflaring Procedures on Root Canal Shaping-Terminology, Basic Concepts, and a Systematic Review. J Endod. 2020; Jun;46(6):707-729.


https://doi.org/10.1016/j.joen.2020.01.023. Epub 2020 Apr 22.


PMid: 32334856.



  1. Berutti E, Cantatore G, Castellucci A, Chiandussi G, Pera F, Migliaretti G, et al. Use of nickel-titanium rotary PathFile to create the glide path: comparison with manual preflaring in simulated root canals. J Endod. 2009;35(3):408-12.
    https://doi.org/10.1016/j.joen.2008.11.021
    PMid:19249606

  2. Paleker F, van der Vyver PJ. Comparison of Canal Transportation and Centering Ability of K-files, ProGlider File, and G-Files: A Micro-Computed Tomography Study of Curved Root Canals. J Endod. 2016;42(7):1105-9.
    https://doi.org/10.1016/j.joen.2016.04.005
    PMid:27178250

  3. Han Y, Hou X-M. Glide path enlargement of curved molar canals using HyFlex EDM glide path file versus PathFile: a comparative study of preparation time and postoperative pain. BMC Oral Health. 2021;21(1):150.
    https://doi.org/10.1186/s12903-021-01512-4
    PMid:33757499 PMCid:PMC7989036

  4. Cassim I, van der Vyver PJ. The importance of glide path preparation in endodontics: a consideration of instruments and literature. SADJ. 2013;68(7):322, 324-7.


PMid:24133951



  1. Thu M, Ebihara A, Adel S, Okiji T. Analysis of Torque and Force Induced by Rotary Nickel-Titanium Instruments during Root Canal Preparation: A Systematic Review. Applied Sciences. 2021;11(7):3079.
    https://doi.org/10.3390/app11073079

  2. Sivas Yılmaz Ö. “Glide Path” in endodontics. Turk Endod J. 2021;6:24-30.


https://doi.org/10.14744/TEJ.2021.02996



  1. Patiño PV, Biedma BM, Liébana CR, Cantatore G, Bahillo JG. The influence of a manual glide path on the separation rate of NiTi rotary instruments. J Endod. 2005;31(2):114-6.
    https://doi.org/10.1097/01.don.0000136209.28647.13
    PMid:15671822

  2. van der Vyver PJ, Vorster M, Paleker F, de Wet FA. Glide path preparation in Endodontics: case report and a literature review of available materials and techniques. South African Dental Journal. 2019;74(3):129-36.
    https://doi.org/10.17159/2519-0105/2019/v74no3a5

  3. Hartmann RC, Peters OA, de Figueiredo J a. P, Rossi-Fedele G. Association of manual or engine-driven glide path preparation with canal centring and apical transportation: a systematic review. Int Endod J. 2018;51(11):1239-52.
    https://doi.org/10.1111/iej.12943
    PMid:29704465

  4. D'Amario M, Baldi M, Petricca R, De Angelis F, El Abed R, D'Arcangelo C. Evaluation of a new nickel-titanium system to create the glide path in root canal preparation of curved canals. J Endod. 2013;39(12):1581-4.
    https://doi.org/10.1016/j.joen.2013.06.037
    PMid:24238451

  5. Alves V de O, Bueno CE da S, Cunha RS, Pinheiro SL, Fontana CE, de Martin AS. Comparison among manual instruments and PathFile and Mtwo rotary instruments to create a glide path in the root canal preparation of curved canals. J Endod. 2012;38(1):117-20.
    https://doi.org/10.1016/j.joen.2011.10.001
    PMid:22152634

  6. Pasqualini D, Bianchi CC, Paolino DS, Mancini L, Cemenasco A, Cantatore G, et al. Computed micro-tomographic evaluation of glide path with nickel-titanium rotary PathFile in maxillary first molars curved canals. J Endod. 2012;38(3):389-93.
    https://doi.org/10.1016/j.joen.2011.11.011
    PMid:22341081

  7. Alovisi M, Cemenasco A, Mancini L, Paolino D, Scotti N, Bianchi CC, et al. Micro-CT evaluation of several glide path techniques and ProTaper Next shaping outcomes in maxillary first molar curved canals. Int Endod J. 2017;50(4):387-97.
    https://doi.org/10.1111/iej.12628
    PMid:26990141

  8. Liu JY, Zhou ZX, Tseng WJ, Karabucak B. Comparison of canal transportation and centering ability of manual K-files and reciprocating files in glide path preparation: a micro-computed tomography study of constricted canals. BMC Oral Health. 2021;23:21(1):83.


https://doi.org/10.1186/s12903-021-01440-3.


PMid: 33622296;



  1. Pui-Yii NL, Jie SZ, Bhatia S, Davamani F, Nagendrababu V. Comparison of Apical Extrusion of Bacteria After Glide path Preparation Between Manual K File, One G Rotary,and WaveOne Gold Glider Reciprocation Preparations. Eur Endod J 2021; 6: 221-5


https://doi.org/10.14744/eej.2021.30602



  1. Gupta R, Ashvin G John, Midhun Ramachandran, Pudu Tirupati, Sushma Shan, Tony Jose and Arvind Bhateja, 2019. “Necessesity of glidepath:a review article.”, International Journal of Current Research. 2019;11(04):2892-2896. https://doi.org/10.24941/ijcr.35025.04.2019

  2. Predin Djuric N, van der Vyver PJ, Vorster M, Vally ZI. Factors influencing apical debris extrusion during endodontic treatment - A review of the literature. SADJ 2021;76 (1):28 – 36.


http://dx.doi.org/10.17159/2519-0105/2021/v76no1a4

Published
2023/08/23
Section
Original Scientific Paper